Description
The model 2042 of Fluke stands out among the locators of cables of the mark since this system of professional use, offers some very effective results when it is applied in all type of structures thanks to his adaptability and application of general use.
This small gadget, gives users the ability to locate both cables of different voltages in walls and underground lines, as well as other types of components, such as fuses or circuit breakers in final circuits. In addition to all this, the Fluke 2042 is also capable of carrying out the localization and subsequent signaling of interruptions and short circuits that have occurred in cables or underground heating systems.
It is also very interesting the large number of applications that are part of those already mentioned, as it also works to perform other alternative checks, such as the location of metal pipes used for water or heating.
In addition, the firmness offered by Fluke has meant that this model does not comply with the basic functions of use, but its presentation is also impressive: this cable locator is supplied by customers accompanied by a specific transport case for this model and the which includes a very useful transmitter and receiver for said specimens.
PRODUCT CHARACTERISTICS
Great capacity. As a result, this is easy to apply to all types of work (including cables without voltage) without the need to use other devices.
Includes a transmitter and receiver
Identification of the signals thanks to its digital coding transmitter
Backlit LCD screen. Therefore, the visualization of the data is facilitated.
Sensitivity of manual or automatic signal
Switchable acoustic receiving signal
Automatic deactivation
Built-in flashlight
Additional transmitters available
TECHNICAL SPECIFICATIONS
Range of voltage measurements – Transmitter: 12 V, 50 V, 120 V, 230 V, 400 V
Frequency range – Transmitter: From 0 to 60 Hz
Output signal – Transmitter: 125 kHz
Voltage – Transmitter: Up to 400 V AC / DC
Location of cables at a certain depth – Receiver: Cables in walls and underground lines from 0 to 2.5 m
Main voltage detection – Receiver: 0 to 0.4 m
Working temperature: From 0 to 40 ° C
Storage temperature: -20 ° C to + 60 ° C
Working altitude: Up to 2000 m
Electrical safety: EN 61010-1
Overvoltage category: Cat. III 300 V
Dimensions:
Transmitter: 190 mm x 85 mm x 50 mm
Receiver: 250 mm x 65 mm x 45 mm
Weight:
Transmitter: 0.45 kg
Receiver: 0.36 kg
The final price of the product varies according to the characteristics of each of the offered versions.
For more information contact us through our contact
Reviews
There are no reviews yet.